Article ID: 256208
Article Last Modified on 10/27/2006
APPLIES TO
- Microsoft Systems Management Server 2.0 Standard Edition
- Microsoft Systems Management Server 2.0 Service Pack 1
This article was previously published under Q256208
SYMPTOMS
When you create a query-based collection on a parent site, all of the expected records are displayed. However, you may be unable to perform the rule evaluation on the child site and the following error message may be displayed:
_com_error exception in MMC Admin UI! Description: Factory Enumeration Failure HRESULT : 0xEEEE0001 File : E:\OPALSP2\mmcadminui\Support\SMS_NMGR\NMGR_NodeData.cpp Line: 272 <><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><> Description: Error enumerating (select * from SMS_CM_RES_COLL_QPL0000F) HRESULT : 0x80041010 File : E:\OPALSP2\mmcadminui\Support\SMS_NWBM\NWBM_CWbemAsyncNodeFactory.cpp Line: 358 <><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><> Description: Error : WBEM_NO_ERROR Operation: GetObject ParameterInfo: SMS_CM_RES_COLL_QPL0000F Wbem error object: instance of __ExtendedStatus { Operation = "GetObject"; ParameterInfo = "SMS_CM_RES_COLL_QPL0000F"; ProviderName = "WinMgmt"; }; Entry Point : Result node factory error QUAKE1 Operation : Command Line: C:\WINNT\System32\mmc.exe "D:\SMS\bin\i386\sms.msc" "____" "" "" "" "" "" "" "" Trace :
CAUSE
When the collection is opened, Systems Management Server (SMS) does not retrieve any rules to evaluate the collection because there are no matching records in the rules tables.
STATUS
Microsoft has confirmed this to be a problem in Systems Management Server version 2.0.
Additional query words: prodsms fail fails