<pre class="fixed_text"> 1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 2 23353:SNA connection to the | <pre class="fixed_text"> 1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 2 23353:SNA connection to the | ||
host has been established | host has been established | ||
<< NJESNA(3402) | |||
1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 4 23224:NJE Connection opened | 1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 4 23224:NJE Connection opened | ||
<< njeconn(459) | |||
1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 4 23230:Waiting for initial | 1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 4 23230:Waiting for initial | ||
contact (FMH-4) from NJE partner application | contact (FMH-4) from NJE partner application | ||
<< njeconn(883) | |||
1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 4 23204:FMH4: optimized fanout | 1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 4 23204:FMH4: optimized fanout | ||
supported | supported | ||
<< njeconn(831) | |||
1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 4 23205:FMH4: signon supported | 1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 4 23205:FMH4: signon supported | ||
<< njeconn(837) | |||
1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 3 23229:Waiting for NJE Signon | 1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 3 23229:Waiting for NJE Signon | ||
from host | from host | ||
<< njeconn(1119) | |||
</pre> | </pre> | ||
After five minutes the following errors are logged: | After five minutes the following errors are logged: | ||
<pre class="fixed_text"> 1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23356:Timeout occurred when | <pre class="fixed_text"> 1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23356:Timeout occurred when | ||
waiting for an LUA verb to complete | waiting for an LUA verb to complete | ||
<< NJESNA(631) | |||
1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23349:Error {Session timeout | 1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23349:Error {Session timeout | ||
occurred} occurred when reading SNA data from the host | occurred} occurred when reading SNA data from the host | ||
<< NJESNA(3599) | |||
1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23217:Error occurred when | 1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23217:Error occurred when | ||
waiting for the signon record from the host | waiting for the signon record from the host | ||
<< njeconn(1126) | |||
1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 00510:Error {Session timeout | 1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 00510:Error {Session timeout | ||
occurred}: The application failed to initialize. | occurred}: The application failed to initialize. | ||
<< stdmain(858) | |||
</pre> | </pre> | ||
Latest revision as of 11:07, 21 July 2020
Article ID: 174694
Article Last Modified on 10/27/2006
APPLIES TO
- Microsoft Exchange Server 4.0 Standard Edition
This article was previously published under Q174694
SYMPTOMS
During initial set up of the LinkAge Exchange-OV/VM Connector (also referred to as the Exchange PROFS Connector), the connector appears to BIND properly to the Remote Spooling Communications Subsystem (RSCS) application, but no mail is exchanged. The last line in the LinkAge Exchange-OV/VM Connector logs for the LME-PROFS-NJE process is:
1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 2 23353:SNA connection to the host has been established << NJESNA(3402) 1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 4 23224:NJE Connection opened << njeconn(459) 1997/10/01 12:02:07- LME-PROFS-NJE(01b7) 4 23230:Waiting for initial contact (FMH-4) from NJE partner application << njeconn(883) 1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 4 23204:FMH4: optimized fanout supported << njeconn(831) 1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 4 23205:FMH4: signon supported << njeconn(837) 1997/10/01 12:02:08- LME-PROFS-NJE(01b7) 3 23229:Waiting for NJE Signon from host << njeconn(1119)
After five minutes the following errors are logged:
1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23356:Timeout occurred when waiting for an LUA verb to complete << NJESNA(631) 1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23349:Error {Session timeout occurred} occurred when reading SNA data from the host << NJESNA(3599) 1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 23217:Error occurred when waiting for the signon record from the host << njeconn(1126) 1997/10/01 12:07:08- LME-PROFS-NJE(01b7) 1 00510:Error {Session timeout occurred}: The application failed to initialize. << stdmain(858)
CAUSE
The connector and RSCS are supposed to exchange a node signon, and the initiating partner is the one with the alphabetically higher node name. The logs above indicate that neither side is initiating the node signon because the LinkAge Exchange-OV/VM Connector is not configured properly. The LOCALNODE= parameter in the Linkage.ini file located in C:\Linkage has to match the LINKID parameter in the RSCS LINK or the LINKDEF statement in the RSCS configuration file, and the PARTNERNODE= parameter has to match the RSCS node ID.
If the RSCS node ID is alphabetically lower than the LINKID name for the connector, then RSCS does not initiate the node signon. And if the LinkAge Exchange-OV/VM Connector is configured so that its LOCALNODE= parameter is alphabetically lower than the PARTNERNODE= parameter, the connector will not initiate either, and you will see the above logged errors as a result.
RESOLUTION
Correct the LOCALNODE= and PARTNERNODE= parameters to match the values specified in the RSCS configuration file. The LOCALNODE= parameter should match the LINKID parameter in the RSCS LINK or LINKDEF statement, and the PARTNERNODE= parameter should match the LOCALID parameter (both definitions are located in the RSCS configuration file).
Additional query words: SEND RECEIVE
Keywords: kbprb KB174694