== CAUSE == | == CAUSE == | ||
Print Server treats the zero-length RU as a unique print job where 0D 0C (CR FF) is sent to the printer. The print server calls | Print Server treats the zero-length RU as a unique print job where 0D 0C (CR FF) is sent to the printer. The print server calls "StartDoc" to start a new document as soon as it receives a request, and "EndDoc" when the document is complete. Even though there is no data submitted to the printer between the "StartDoc" and "EndDoc" calls, the printer will still print a form feed (FF). | ||
</div> | </div> | ||
Line 81: | Line 81: | ||
There are two possible workarounds for this issue: | There are two possible workarounds for this issue: | ||
<ol> | <ol> | ||
<li>Configure the print session to use a PDF file. The PDF file uses | <li>Configure the print session to use a PDF file. The PDF file uses "StartDocPrinter" and "EndDocPrinter" which do not automatically produce a FF. For instructions on configuring PDF files, refer to the SNA Server online help Chapter 6 Printer Definition Files.<br /> | ||
<br /> | <br /> | ||
-OR-</li> | -OR-</li> |
Latest revision as of 11:05, 21 July 2020
Article ID: 170583
Article Last Modified on 12/4/2007
APPLIES TO
- Microsoft Host Integration Server 2000 Standard Edition
- Microsoft SNA Server 3.0 Service Pack 4
- Microsoft SNA Server 4.0
- Microsoft SNA Server 3.0 Service Pack 2
- Microsoft SNA Server 3.0 Service Pack 3
- Microsoft SNA Server 3.0 Service Pack 4
- Microsoft SNA Server 4.0
- Microsoft SNA Server 4.0 Service Pack 1
- Microsoft SNA Server 4.0 Service Pack 2
- Microsoft SNA Server 4.0 Service Pack 3
- Microsoft Host Integration Server 2004 Standard Edition
This article was previously published under Q170583
SYMPTOMS
When a zero-length RU is sent to the SNA print server as part of a host print job, a blank page will be printed. The following is an example of a zero-length RU as captured in a SNA Server Data Link Control Message trace:
04160080->01020101 DLC DATA DAF:EC OAF:01 ODAI:off Normal RQE FMD BC EC DR1 PI BB EB ---- Header at address 01034418, 1 elements ---- 04B00004 00002C00 EC010004 01002102 <......,.......!.> ---- Element at address 0152D5A4, start 10, end 12 ---- 0391C0 <.j. >
The Element portion of the preceding frame contains a Request Header (RH) of x'0391C0', but no actual data.
CAUSE
Print Server treats the zero-length RU as a unique print job where 0D 0C (CR FF) is sent to the printer. The print server calls "StartDoc" to start a new document as soon as it receives a request, and "EndDoc" when the document is complete. Even though there is no data submitted to the printer between the "StartDoc" and "EndDoc" calls, the printer will still print a form feed (FF).
RESOLUTION
There are two possible workarounds for this issue:
- Configure the print session to use a PDF file. The PDF file uses "StartDocPrinter" and "EndDocPrinter" which do not automatically produce a FF. For instructions on configuring PDF files, refer to the SNA Server online help Chapter 6 Printer Definition Files.
-OR- - Use the DelayPrintStart Registry parameter as discussed in the following Microsoft Knowledge Base article:
172283 Title: Blank Page Is Printed Between Each Print Job
Keywords: kbprb KB170583