Microsoft KB Archive/169593: Difference between revisions
(stage2) |
m (1 revision imported: importing part 2) |
(No difference)
|
Latest revision as of 21:50, 16 July 2020
PRB: GP Fault on DC_BINADJUST if No Input Bins Are Selectable |
Q169593
The information in this article applies to:
- Microsoft Win32 Device Driver Kit (DDK) Windows 95
SYMPTOMS
A printer minidriver may cause a GP Fault when processing DC_BINADJUST (wIndex == 19) if the driver does not create any input bins or does not make any input bins selectable in UniDrv.
CAUSE
The fault occurs when the driver passes the DC_BINADJUST down to UniDrvDeviceCapabilities(). UniDrvDeviceCapabilities() does not check for null string pointers. If no input bins are selected, the bin name strings will be null and a GP Fault will occur.
RESOLUTION
Printer minidrivers must always create at least one selectable input bin. You can create an input bin in UniTool by selecting Printer Data/Paper Info/Source. To make the bin selectable using UniTool, select Printer Data/Model Data, and make sure at least one bin is enabled for Paper Sources in the list of Supported Attributes.
STATUS
This behavior is by design.
Keywords : kbprint
Issue type :
Technology : kbAudDeveloper kbWin95search kbWinDDKSearch kbWin32sSearch kbWin32DDK95 kbWin32DDKSearch
Last Reviewed: March 5, 1999 |