== SYMPTOMS == | == SYMPTOMS == | ||
The Archive 2150/2250 QIC SCSI tape drive (Viper 150, Viper 250) does not correctly respond with the number of bytes transferred. This is a condition known as an | The Archive 2150/2250 QIC SCSI tape drive (Viper 150, Viper 250) does not correctly respond with the number of bytes transferred. This is a condition known as an "under run." | ||
</div> | </div> | ||
Line 60: | Line 60: | ||
== WORKAROUND == | == WORKAROUND == | ||
Use one of the SCSI miniports that have been tested out and correctly handle under runs: AHA154X.SYS, AHA174X.SYS, SPARROW.SYS, FD16_700.SYS, FD8XX,SYS, and SPOCK.SYS. Except for the Ultrastor 24, these are all the | Use one of the SCSI miniports that have been tested out and correctly handle under runs: AHA154X.SYS, AHA174X.SYS, SPARROW.SYS, FD16_700.SYS, FD8XX,SYS, and SPOCK.SYS. Except for the Ultrastor 24, these are all the "core" adapters. | ||
</div> | </div> |
Latest revision as of 09:24, 20 July 2020
Article ID: 102377
Article Last Modified on 10/31/2006
APPLIES TO
- Microsoft Windows NT Advanced Server 3.1
- Microsoft Windows NT Workstation 3.1
- Microsoft Windows NT Advanced Server 3.1
This article was previously published under Q102377
SYMPTOMS
The Archive 2150/2250 QIC SCSI tape drive (Viper 150, Viper 250) does not correctly respond with the number of bytes transferred. This is a condition known as an "under run."
CAUSE
A firmware error causes the Archive 2150/2250 to do this.
WORKAROUND
Use one of the SCSI miniports that have been tested out and correctly handle under runs: AHA154X.SYS, AHA174X.SYS, SPARROW.SYS, FD16_700.SYS, FD8XX,SYS, and SPOCK.SYS. Except for the Ultrastor 24, these are all the "core" adapters.
Additional query words: prodnt
Keywords: kbother KB102377