Microsoft KB Archive/103027: Difference between revisions
(importing KB archive) |
m (Text replacement - """ to """) |
||
Line 50: | Line 50: | ||
== MORE INFORMATION == | == MORE INFORMATION == | ||
The UPS service is started from the Control Panel. It is used to configure desired options and operation of the UPS hardware. You can enable the service by selecting the | The UPS service is started from the Control Panel. It is used to configure desired options and operation of the UPS hardware. You can enable the service by selecting the "Uninterruptible Power Supply is installed on:" check box.<br /> | ||
<br /> | <br /> | ||
The Remote UPS Shutdown configuration option allows the Windows NT system to tell the UPS to turn off. This is done when Windows NT is gracefully shutting down.<br /> | The Remote UPS Shutdown configuration option allows the Windows NT system to tell the UPS to turn off. This is done when Windows NT is gracefully shutting down.<br /> |
Latest revision as of 09:25, 20 July 2020
Article ID: 103027
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Advanced Server 3.1
- Microsoft Windows NT Workstation 3.1
This article was previously published under Q103027
The uninterruptible power supply (UPS) service in Windows NT has an unexpected behavior in the user interface. If the Remote UPS Shutdown check box is not selected, the signal level option buttons are still available. This article describes how and why this unusual behavior is required.
MORE INFORMATION
The UPS service is started from the Control Panel. It is used to configure desired options and operation of the UPS hardware. You can enable the service by selecting the "Uninterruptible Power Supply is installed on:" check box.
The Remote UPS Shutdown configuration option allows the Windows NT system to tell the UPS to turn off. This is done when Windows NT is gracefully shutting down.
If the Remote UPS Shutdown check box is selected, this indicates that the UPS device supports this functionality; the appropriate signal level must then be selected to indicate how it works.
If the Remote UPS Shutdown check box is clear (not selected), the signal level option buttons are still available. The expected behavior is that if the option is disabled, the option buttons would be unavailable; but this is not the case. If the Remote UPS Shutdown check box is clear and the signal level option buttons are available, there are two possibilities:
- The UPS device does not support this functionality. Therefore, it doesn't matter what the signal level option buttons are set to.
-or-
- The UPS device does support this functionality, but you do not want to use it.
In this case, you still need set the signal level option button that the UPS expects so that the UPS does not work incorrectly. Even if you do not want to use this feature, the UPS is still going to interpret the signals on this line. If it receives a certain signal, it will shut itself down.
Previously, if you did not want to use this feature on your UPS, the default value assumed for the signal would (for 50 percent of UPS's) result in the UPS device shutting itself off as soon as the power failed, which is not desirable.
Additional query words: prodnt active not gray grey