Article ID: 931816
Article Last Modified on 3/22/2007
APPLIES TO
- Microsoft SoftGrid for Terminal Services
- Microsoft SoftGrid for Windows Desktops
SYMPTOMS
A Microsoft Common Console document does not open. Additionally, you receive the following error code:
CAUSE
This problem occurs when the .msc file is specified in the FILENAME attribute of the .osd file. The .msc file must be specified in the PARAMETERS attribute. Additionally, the Microsoft Management Console (MMC) executable file must be specified in the FILENAME attribute.
The following example shows a correct FILENAME attribute and a correct PARAMETERS attribute:
FILENAME="%SystemRoot%\system32\mmc.exe" PARAMETERS=""C:\Program Files\Softricity\SoftGrid Management Console\SftMMC.msc""
Note When a space exists in the PARAMETERS attribute path, the path must be enclosed in """ characters. You cannot use only quotation mark characters (").
MORE INFORMATION
This problem is a known application-specific sequencing issue in MMC.
For more information about this error message, click the following article number to view the article in the Microsoft Knowledge Base:
931151 SoftGrid Client "Error code: xxxxxx-xxxxxx2C-800700C1"
Keywords: kbexpertiseinter kbhowto KB931816