Article ID: 262601
Article Last Modified on 8/7/2007
APPLIES TO
- Microsoft Visual InterDev 6.0 Standard Edition
- Microsoft Data Access Components 2.1
This article was previously published under Q262601
SYMPTOMS
When you use the SQL Builder window in Visual InterDev 6.0, you may find that when you right-click on a table in the Diagram pane that no menu appears.
STATUS
Microsoft has confirmed that this is a bug in the Microsoft products that are listed at the beginning of this article. This bug was corrected in the next service pack for Visual Studio 6.0.
For additional information about Visual Studio service packs, click the following article numbers to view the articles in the Microsoft Knowledge Base:
194022 INFO: Visual Studio 6.0 Service Packs, What, Where, Why
194295 HOWTO: Tell That a Visual Studio Service Pack Is Installed
To download the latest Visual Studio service pack, visit the following Microsoft Web site:
MORE INFORMATION
Steps to Reproduce Behavior
- Right-click the Global.asa in the Project Explorer and select Add Data Connection. Follow the steps to create a connection.
- Right-click the new data connection and select Add Data Command.
- In the Command Properties dialog box, on the General tab, select the SQL Statement option, and then click the SQL Builder button.
- On the Data View tab, expand the database that corresponds with the data connection that you created. Then expand the Table section that is found under that connection.
- Drag one of the tables from the Data View tab and drop it in the Diagram pane of the SQL Builder window.
- Right-click the table in the Diagram pane. No menu will appear.
Additional query words: sp4
Keywords: kbbug kbdatabase kbfix kbvisid600fix kbvs600sp4fix kbvs600sp5fix KB262601