Article ID: 92881
Article Last Modified on 10/15/2003
APPLIES TO
- Microsoft Windows for Workgroups 3.1
- Microsoft Windows for Workgroups 3.11
This article was previously published under Q92881
SYMPTOMS
If you install Windows for Workgroups on a machine that was once an IBM OS/2 Lan Server client, you may receive a "Netbind" error followed by an "Undefined Dynalink" error when you start Windows for Workgroups.
CAUSE
These errors indicate that there are still IBM Lan Server drivers in the CONFIG.SYS and AUTOEXEC.BAT files.
RESOLUTION
The following lines need to be removed or remarked out (using REM) from the CONFIG.SYS file:
- Any lines that reference PROTMAN.EXE (Windows for Workgroups uses PROTMAN.DOS)
- Any lines that reference DXMEOMOD.SYS
In the AUTOEXEC.BAT file, any reference to the Lan Server software directory in the PATH= statement should be removed.
Additional query words: 3.10 3.11
Keywords: KB92881