Microsoft KB Archive/900344

From BetaArchive Wiki
< Microsoft KB Archive
Revision as of 18:24, 18 July 2020 by 3155ffGd (talk | contribs) (importing KB archive)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Article ID: 900344

Article Last Modified on 11/15/2007



APPLIES TO

  • Microsoft BizTalk Adapter 2.0 for mySAP Business Suite




SYMPTOMS

The Microsoft BizTalk Adapter 2.0 for mySAP Business Suite adapter may not generate a schema for certain BAPIs. You may receive an error message that is similar to the following:

1. Error occured while generating schema for :BAPI_ALM_NOTIF_CREATE Error returned : c:\Documents and Settings\Administrator\Local Settings\Temp\c-tzbayv.4.cs(28,19) : error CS0542: 'BAPIFLAG': member names cannot be the same as their enclosing type

CAUSE

This problem occurs when the SAP structure name and the parameter name are the same.

RESOLUTION

Hotfix information

A supported hotfix is now available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next service pack that contains this hotfix.

To resolve this problem, submit a request to Microsoft Online Customer Services to obtain the hotfix. To submit an online request to obtain the hotfix, visit the following Microsoft Web site:

Note If additional issues occur or any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. To create a separate service request, visit the following Microsoft Web site:

Prerequisites

No prerequisites are required.

Restart requirement

You do not have to restart the computer after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace any other hotfixes.

File information

The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.

   Date         Time   Version    Size    File name
   ------------------------------------------------------------------
   25-May-2005  23:41  2.0.337.0  94,208  Rfcschemaproxygenerator.dll

Note Because of file dependencies, the most recent hotfix that contains these files may also contain additional files.

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

MORE INFORMATION

This hotfix also modifies how the Rfcschemaproxygenerator.dll file enumerates columns. After you apply this hotfix, the Rfcschemaproxygenerator.dll file uses the column name instead of the column ordinal number to enumerate columns.

For more information, click the following article number to view the article in the Microsoft Knowledge Base:

824684 Description of the standard terminology that is used to describe Microsoft software updates


Keywords: kbbiztalk2004presp2fix kbbiztalk2000sp2fix kbbug kbfix kbpubtypekc kbhotfixserver kbqfe KB900344