Switch Settings for the HP 7475A Plotter PSS ID Number: Q30875 Article last modified on 09-12-1991 PSS database name: W_Win3

2.03

WINDOWS

Summary: The following are the appropriate switch settings for the Hewlett-Packard 7475A Plotter supported under Windows:

Parity S2 Off Parity S1 Off

D Met A4 Y Off D Met A4 US On D Met A4 A3 Off

Baud B4 On Baud B3 Off Baud B2 On Baud B1 Off