Article ID: 264716
Article Last Modified on 2/20/2007
APPLIES TO
- Microsoft Windows 2000 Server
- Microsoft Windows 2000 Advanced Server
- Microsoft Windows 2000 Professional Edition
This article was previously published under Q264716
SYMPTOMS
When you set a capture filter in Network Monitor to capture only frames that are sent to the the active monitor address on a Token Ring network, you may also see frames that are sent to the broadcast address in the resultant capture.
CAUSE
The macro that compares the MAC addresses contains an error.
RESOLUTION
To resolve this problem, obtain the latest service pack for Windows 2000. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:
260910 How to Obtain the Latest Windows 2000 Service Pack
The English version of this fix should have the following file attributes or later:
Date Time Version Size File name ----------------------------------------------------- 06/02/2000 05:33p 5.00.2195.2096 37,456 Nmnt.sys
STATUS
Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in Windows 2000 Service Pack 2.
MORE INFORMATION
For additional information about how to install Windows 2000 and Windows 2000 hotfixes at the same time, click the article number below to view the article in the Microsoft Knowledge Base:
249149 Installing Microsoft Windows 2000 and Windows 2000 Hotfixes
Keywords: kbhotfixserver kbqfe kbbug kbfix kbwin2000presp2fix KB264716