Article ID: 221196
Article Last Modified on 9/22/2005
APPLIES TO
- Microsoft Commercial Internet System 2.0
- Microsoft Windows NT Server 4.0 Standard Edition
This article was previously published under Q221196
SYMPTOMS
When Remote Authentication Dial-In User Service (RADIUS) uses an ODBC data source for validation data, it cannot re-establish a connection to the ODBC data source if the connection is broken (database crash, database maintenance, network storm, hardware problems, electrical outages).
CAUSE
No retry logic was implemented for ODBC, so the service fails to start if the database is unavailable, and fails to reconnect if the server is unreachable for any reason.
RESOLUTION
Windows NT Server or Workstation 4.0
To resolve this problem, obtain the latest service pack for Windows NT 4.0 or the individual software update. For information on obtaining the latest service pack, please go to:
- 152734 how to obtain the latest windows nt 4.0 service pack
For information on obtaining the individual software update, contact Microsoft Product Support Services. For a complete list of Microsoft Product Support Services phone numbers and information on support costs, please go to the following address on the World Wide Web:
Windows NT Server 4.0, Terminal Server Edition
To resolve this problem, obtain the latest service pack for Windows NT Server 4.0, Terminal Server Edition. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:
152734 How to Obtain the Latest Windows NT 4.0 Service Pack
STATUS
Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article.
This problem was first corrected in Windows NT Server version 4.0, Terminal Server Edition Service Pack 6.
Keywords: kbbug kbfix kbqfe kbhotfixserver KB221196