Article ID: 197845
Article Last Modified on 10/31/2006
APPLIES TO
- Microsoft Windows NT Server 4.0 Standard Edition
- Microsoft Windows NT Server 4.0 Enterprise Edition
This article was previously published under Q197845
SYMPTOMS
After you upgrade to Service Pack 4 (SP4) on an NTFS partition with a SMART-2 array controller, the system may stop responding (hang). This happens when the system starts and the following blue screen is displayed during the loading phase of the drivers:
CAUSE
This problem is because of an outdated SMART-2 firmware version 1.36 (dated 12 June 1996).
RESOLUTION
To resolve this problem, upgrade SMART-2 array firmware with version 3.08 (dated 13 Nov 1998) or later, prior to upgrading to SP4. You can get the latest firmware version from the following address:
ftp://ftp.compaq.com/pub/softpaq/sp8501-9000/sp8560.exe
Compaq Options ROMPaq firmware upgrade diskette ver 2.49 Rev a
Also, verify the latest Compaq SSD for Windows NT is installed on your system, prior to upgrading to SP4. The current SSD version is 2.10 Rev.A:
http://www.compaq.com/support/files/server/softpaqs/WINNT/NTSSD400.html
Compaq Support Software for Microsoft Windows NT 4.00
MORE INFORMATION
This problem was seen using the SMART-2 firmware rev. 1.36.(12-Jun-96) The problem was fixed using the SMART-2 firmware rev. 3.08 (13-Nov-98) Intermediate SMART-2 firmware versions were not tested.
The third-party products discussed here are manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.
Additional query words: SP4 COMPAQ SMART array
Keywords: kbprb KB197845