Article ID: 182683
Article Last Modified on 3/18/2004
APPLIES TO
- Microsoft COM Transaction Integrator for CICS and IMS 1.0, when used with:
- Microsoft SNA Server 4.0
This article was previously published under Q182683
SYMPTOMS
After starting the Import COBOL Wizard, it may become impossible to view or select the Windows taskbar. This problem occurs after browsing to select the import file. When this problem occurs, the taskbar will not be available until the Import COBOL Wizard has finished running. This problem occurs if both of the following conditions are true:
- The taskbar has been set to "Auto hide" mode. -and-
- While the taskbar is hidden, the window for Component Builder, which is being used to create a component library, has been resized to cover the entire monitor screen area, although not actually maximized.
WORKAROUND
To work around this problem, resize the CB window so that at least a very small portion of the background window is visible. After doing this, the problem will not occur while using the Import COBOL Wizard.
STATUS
Microsoft has confirmed this to be a problem in Microsoft COM Transaction Integrator for CICS and IMS version 1.0.
This problem was corrected in the latest SNA Server version 4.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: comti task bar
Keywords: kbbug kbfix KB182683