SYMPTOMS
CPIC reports CM_PRODUCT_SPECIFIC_ERROR (20) when you try to issue an MC_ALLOCATE after you issue a RECEIVE_ALLOCATE and receive a TP_ID. An APPC trace will reveal a primary and secondary error codes indicating that the TP_ID is incorrect. The following event will be registered in the Application Log:
CAUSE
The CPIC library was not handling APPC TP_IDs correctly if an application issues a Receive, cmrcv(), and then issues an Allocate, cmallc().
STATUS
Microsoft has confirmed this to be a problem in Microsoft SNA Server version 2.11 Service Pack 1.
This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: api sp1 prodsna