Article ID: 139841
Article Last Modified on 10/31/2006
APPLIES TO
- Microsoft Windows NT Workstation 3.51
This article was previously published under Q139841
SYMPTOMS
SNMP on Windows NT Workstation return a corrupt value when the Interface Object's MAC address is read. SNMP returns four or five bytes of the six byte address.
MORE INFORMATION
The following command line entries will reproduce the problem. Notice that the Windows NT server returns a correct value for ifPhysAddress.2 while the two workstations return corrupt information.
C:\users\default>snmputil walk <computernmae> public .1.3.6.1.2
Windows NT Server 3.51 Service Pack 2:
Variable = interfaces.ifTable.ifEntry.ifDescr.2
Value = OCTET STRING - Intel EtherExpress PRO Adapter
Variable = interfaces.ifTable.ifEntry.ifPhysAddress.2
Value = OCTET STRING - <0x0><0xaa><0x0><0xb5><0x1a><0x95>
Windows NT Workstation 3.51 Service Pack 1:
Variable = interfaces.ifTable.ifEntry.ifDescr.2
Value = OCTET STRING - Intel EtherExpress 16 Miniport/
Variable = interfaces.ifTable.ifEntry.ifPhysAddress.2
Value = OCTET STRING - <0x0><0xaa><0x0>7?<0xce>
Windows NT Workstation 3.51 Service Pack 2:
Variable = interfaces.ifTable.ifEntry.ifDescr.4
Value = OCTET STRING - Intel EtherExpress PRO Adapter
Variable = interfaces.ifTable.ifEntry.ifPhysAddress.2
Value = OCTET STRING - <0x0><0xaa><0x0>`<0xd3><0xce>
STATUS
Microsoft has confirmed this to be a problem in Windows NT Workstation version 3.51 We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
Additional query words: prodnt tcpip sp1 sp2 media access control
Keywords: kbnetwork KB139841