Article ID: 132709
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Workstation 3.5
- Microsoft Windows NT Server 3.5
This article was previously published under Q132709
SYMPTOMS
When you configure Sybase SQLServer with Master Listeners to include the IPX/SPX Compatible Transport (NWLink) and install Windows NT 3.5 Service Pack 2 (SP2), one or all of the following error messages appear when you attempt to start Sybase SQLServer services:
-or-
-or-
-or-
-or-
-or-
RESOLUTION
To correct this problem, do one of the following:
- Restore NTDLL.DLL from the original Windows NT 3.5 compact disc (CD) or floppy disks to the %SYSTEMROOT%\SYSTEM32 directory.
-or-
- Upgrade to Windows NT 3.51.
STATUS
Microsoft has confirmed this to be a problem in Windows NT 3.5 Service Pack 2. This problem was corrected in Windows NT version 3.51.
SQLServer is manufactured by Sybase, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.
Additional query words: prodnt sql server local system
Keywords: KB132709