Article ID: 127955
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Workstation 3.5
- Microsoft Windows NT Server 3.5
This article was previously published under Q127955
SYMPTOMS
Under Windows NT 3.5, if the LPD Server is issued an LPRM command (remote removal of a job) from an LPR client (such as UNIX), any jobs with double digits (10 or >) are not removed properly. However, single digit jobs (1 to 9) are removed properly.
WORKAROUND
To work around this problem, remove pending jobs sent from an LPR client using Print Manager on the LPD Server or Print Manager from a Windows NT client.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.5. This problem was corrected in Windows NT version 3.51.
Additional query words: prodnt