Microsoft KB Archive/127822

From BetaArchive Wiki
Knowledge Base


EISA Configuration Utility for Compaq Prosignia

Article ID: 127822

Article Last Modified on 11/1/2006



APPLIES TO

  • Microsoft Windows NT Advanced Server 3.1
  • Microsoft Windows NT Workstation 3.1
  • Microsoft Windows NT Advanced Server 3.1
  • Microsoft Windows NT Workstation 3.5
  • Microsoft Windows NT Server 3.5



This article was previously published under Q127822

Internal modems used with Windows NT require that serial port 1 or serial port 2 be disabled. Compaq Prosignia EISA configuration utilities prior to version 2.22 revision E fail to disable the specified port. The port is reported as available in Control Panel (Ports) even though the EISA configuration utility reports it disabled.

A new version of the EISA configuration utility (version 2.22 revision E) is available on the Compaq FTP server (FTP.COMPAQ.COM \pub\softpaq\diagnostic-setup) and the Compaq bulletin board system (BBS) at (713) 378-1418. The updated EISA configuration utility is in the compressed file SP1016.ZIP. After you uncompress the file, run SP1016.EXE and then follow the directions in README3H.1ST.


Additional query words: prodnt 3.10 com comm config com1 com2

Keywords: KB127822