Error 234 When Using NET VIEW in Windows for Workgroups 3.11 |
Q127764
The information in this article applies to:
- Microsoft Windows NT Advanced Server, version 3.1
- Microsoft Windows NT Workstation versions 3.1, 3.5, 3.51, 4.0
- Microsoft Windows NT Server versions 3.1, 3.5, 3.51, 4.0
- Microsoft Windows for Workgroups
SYMPTOMS
When you run NET VIEW from a Windows for Workgroups version 3.11 client system to view the shares on a Windows NT computer, the following error message appears:
Error 234
If you attempt a similar operation in Windows for Workgroups File Manager by selecting a Windows NT computer, the following error message appears:
An internal Lanman error has occurred.
CAUSE
There may be a corrupt share on the Windows NT computer.
RESOLUTION
To correct this problem, try one or more of the following steps:
- Disconnect from all shares on the Windows NT computer (including hidden shares such as c$ and ipc$) and then reestablish the connections.
- If long share names are being used for either file shares or printer shares, try renaming the share to contain no more than 12 characters.
- Delete all the shares on the server and then recreate them.
Additional query words: prodnt 3.10 3.11 wfw wfwg
Keywords :
Issue type :
Technology : kbWinNTsearch kbWinNTWsearch kbWinNTW400 kbWinNTW400search kbWinNT351xsearch kbWinNT350xsearch kbWinNT400xsearch kbWinNTW350 kbWinNTW350xsearch kbWinNTW351xsearch kbWinNTW351 kbWinNTW310 kbWinNTSsearch kbWinNTS400xsearch kbWinNTS400 kbWinNTS351 kbWinNTS350 kbWinNTS310 kbWinNTAdvSerSearch kbWinNTAdvServ310 kbWinNTS351xsearch kbWinNTS350xsearch kbWinNTS310xsearch kbAudDeveloper kbWinNT310xSearch kbWinNTW310Search kbWFWSearch
Last Reviewed: November 22, 2000 |