Microsoft KB Archive/127764

From BetaArchive Wiki

Error 234 When Using NET VIEW in Windows for Workgroups 3.11

Q127764



The information in this article applies to:


  • Microsoft Windows NT Advanced Server, version 3.1
  • Microsoft Windows NT Workstation versions 3.1, 3.5, 3.51, 4.0
  • Microsoft Windows NT Server versions 3.1, 3.5, 3.51, 4.0
  • Microsoft Windows for Workgroups





SYMPTOMS

When you run NET VIEW from a Windows for Workgroups version 3.11 client system to view the shares on a Windows NT computer, the following error message appears:

Error 234

If you attempt a similar operation in Windows for Workgroups File Manager by selecting a Windows NT computer, the following error message appears:

An internal Lanman error has occurred.



CAUSE

There may be a corrupt share on the Windows NT computer.



RESOLUTION

To correct this problem, try one or more of the following steps:


  • Disconnect from all shares on the Windows NT computer (including hidden shares such as c$ and ipc$) and then reestablish the connections.
  • If long share names are being used for either file shares or printer shares, try renaming the share to contain no more than 12 characters.
  • Delete all the shares on the server and then recreate them.

Additional query words: prodnt 3.10 3.11 wfw wfwg

Keywords :
Issue type :
Technology : kbWinNTsearch kbWinNTWsearch kbWinNTW400 kbWinNTW400search kbWinNT351xsearch kbWinNT350xsearch kbWinNT400xsearch kbWinNTW350 kbWinNTW350xsearch kbWinNTW351xsearch kbWinNTW351 kbWinNTW310 kbWinNTSsearch kbWinNTS400xsearch kbWinNTS400 kbWinNTS351 kbWinNTS350 kbWinNTS310 kbWinNTAdvSerSearch kbWinNTAdvServ310 kbWinNTS351xsearch kbWinNTS350xsearch kbWinNTS310xsearch kbAudDeveloper kbWinNT310xSearch kbWinNTW310Search kbWFWSearch


Last Reviewed: November 22, 2000
© 2001 Microsoft Corporation. All rights reserved. Terms of Use.