Article ID: 117370
Article Last Modified on 10/31/2006
APPLIES TO
- Microsoft Windows NT Advanced Server 3.1
- Microsoft Windows NT Workstation 3.1
- Microsoft Windows NT Advanced Server 3.1
- Microsoft Windows NT Server 4.0 Standard Edition
- Microsoft Windows NT Workstation 4.0 Developer Edition
This article was previously published under Q117370
SYMPTOMS
When you attempt to run the NetWare utility RCONSOLE from Windows NT using the NCC (NetWare Compatible Client for Windows NT) software, the following error message may appear:
WORKAROUND
Check for the following entries in the AUTOEXEC.NT file:
lh %SystemRoot%\system32\nw16 lh %SystemRoot%\system32\vwipxspx
If the entries are present, check to see if the following associated files actually exist:
%SystemRoot%\system32\nw16.exe %SystemRoot%\system32\vwipxspx.exe %SystemRoot%\system32\vwipxspx.dll
If these associated files do not exist, remove the NCC software and reinstall it to correctly copy these files to their appropriate locations.
Additional query words: prodnt
Keywords: kbinterop KB117370