Article ID: 824634
Article Last Modified on 10/26/2005
APPLIES TO
- Microsoft Host Integration Server 2000 Standard Edition
- Microsoft Host Integration Server 2000 Service Pack 1
SYMPTOMS
After you apply the Q814978 hotfix, you may experience problems if multiple nested user-defined types (UDTs) contain the OCCURS Depending On (ODO) clause when the UDTs send data to the host. All data after a nested ODO clause will be sent as null values (hexadecimal 00).
For additional information about Q814978, click the following article number to view the article in the Microsoft Knowledge Base:
814978 COMTI data conversion does not succeed when there are four or more nested UDTs
RESOLUTION
Service pack information
To resolve this problem, obtain the latest service pack for Microsoft Host Integration Server 2000. For more information, click the following article number to view the article in the Microsoft Knowledge Base:
328152 How to obtain the latest service pack for Host Integration Server 2000
Hotfix information
The English version of this hotfix has the file attributes (or later) that are listed in the following table. The dates and times for these files are listed in coordinated universal time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.
Date Time Version Size File name ------------------------------------------------------------ 06-Aug-2003 22:44 5.0.0.934 37,136 Capture.dll 06-Aug-2003 22:44 5.0.0.934 323,856 Cedrmsgs.dll 06-Aug-2003 22:44 5.0.0.934 33,040 Comticontext.dll 06-Aug-2003 22:44 5.0.0.934 147,728 Convert.dll 06-Aug-2003 22:44 5.0.0.934 74,000 Convertprim.dll 06-Aug-2003 22:44 5.0.0.934 33,040 Dpl1.dll 06-Aug-2003 22:45 5.0.0.934 823,568 Dtcob390.dll 06-Aug-2003 22:44 5.0.0.934 37,136 Playback.dll 06-Aug-2003 22:44 5.0.0.934 78,096 Readlib.dll 06-Aug-2003 22:44 5.0.0.934 123,152 Tadtlb.dll 06-Aug-2003 22:44 5.0.0.934 114,960 Tagen.dll 06-Aug-2003 22:44 5.0.0.934 82,192 Tranlu62.dll 06-Aug-2003 22:44 5.0.0.934 110,864 Trantcp.dll 06-Aug-2003 22:44 5.0.0.934 49,424 Turnaround.dll 06-Aug-2003 22:45 5.0.0.870 950,272 Componentbuilder.exe 29-Mar-2003 01:15 838,423 Comticb.chm 29-Mar-2003 01:15 812,988 Resnapin.chm
Note Because of file dependencies, the most recent fix that contains these files may also contain additional files.
STATUS
Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section. This problem was corrected in Microsoft Host Integration Server 2000 Service Pack 2.
MORE INFORMATION
The following is an example of a data definition that fails:
01 INPUT-DATA-AREA. 05 UDT-LEVEL-1. 15 UDT-LEVEL-2A. 20 LENGTH2A PIC S9(9) COMP. 20 UDT-LEVEL-3 OCCURS 10000 TIMES DEPENDING ON LENGTH2A. 25 LENGTH3 PIC S9(9) COMP. 25 MYDATA OCCURS 5000 TIMES DEPENDING ON LENGTH3 PIC X. 15 UDT-LEVEL-2B. 20 MYSTRING PIC X(9). 20 BALANCE PIC S9(7)V99 COMP-3.
In this example, the data that is sent to the host for MYSTRING and BALANCE is made up of all null characters (hexadecimal 00) instead of the data that is passed to COMTI by the client program. This problem only occurs if you use the ODO clause.
Keywords: kbbug kbfix kbqfe kbhotfixserver KB824634