FORMAT.COM Cannot Be Directly Run with Parameters |
Q58242
The information in this article applies to:
- Microsoft Windows versions 3.0, 3.0a
SYMPTOMS
If you create a PIF file that runs the MS-DOS version 3.x FORMAT.COM utility; the PIF may have a question mark in the Parameters field. When you run the PIF, enter a: or b: as the parameter, and then choose the OK button, FORMAT.COM will start and then print the following error message:
Drive letter must be specified
FORMAT.COM then exits without doing anything.
This PIF file works properly with Windows/386 Versions 2.x.
WORKAROUND
To work around this problem, do not run FORMAT.COM directly; instead, run FORMAT.COM from the MS-DOS command prompt, or run FORMAT.COM from the file manager under the Disk Menu.
STATUS
Microsoft has confirmed this to be a problem with Windows version 3.0. We are researching this problem and will post new information here as it becomes available.
This problem does not occur with MS-DOS version 4.0 or 4.01.
Additional query words: 3.00 3.00a
Keywords :
Issue type :
Technology : kbWin3xSearch kbWin300 kbWin300a
Last Reviewed: October 23, 1999 |