Article ID: 230601
Article Last Modified on 9/22/2005
APPLIES TO
- Microsoft SNA Server 4.0 Service Pack 2
- Microsoft COM Transaction Integrator for CICS and IMS 4.0 SP2
This article was previously published under Q230601
SYMPTOMS
Method parameters defined using automation types of Integer, Long, Single, Double, Currency, or Decimal are incorrectly mapped to COBOL data type of type PIC 9(n) LEADING SEPARATE DISPLAY (or PIC 9(n)V9(n)LEADING SEPARATE DISPLAY) in Component Builder (CB) when you build new COM Transaction Integrator (COMTI) components.
The first indication this problem exists may be a run time error. The first indication of the possibility of this problem is a run time error. The following error message is posted to the Windows NT application event log:
Because this error message may accurately indicate a problem of the application code, a further step is necessary to demonstrate a COMTI problem exists instead. Export COBOL from the COMTI component library. You can see the variables in question defined with the "LEADING SEPARATE DISPLAY" attribute.
CAUSE
COMTI is not handling the conversion properly for unsigned DISPLAY.
RESOLUTION
To resolve this problem, obtain the latest service pack for SNA Server version 4.0. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:
215838 How to Obtain the Latest SNA Server Version 4.0 Service Pack
STATUS
Microsoft has confirmed that this is a problem in Microsoft SNA Server version 4.0SP2. This problem was first corrected in SNA Server version 4.0 Service Pack 3.
Keywords: kbbug kbfix kbsna400sp3fix kbqfe kbhotfixserver KB230601