Article ID: 165135
Article Last Modified on 10/28/2006
APPLIES TO
- Microsoft Exchange Client 5.5
- Microsoft Exchange Client 4.0
This article was previously published under Q165135
SYMPTOMS
When the Microsoft Exchange Client is installed on a workstation for the very first time, the Setup program requires that you restart Windows at the end of Setup. When you use quiet mode setup (setup /q), this restart occurs automatically. Even if you remove Microsoft Exchange Client completely and run Setup again, it will not require a restart on subsequent occasions.
CAUSE
The Setup program uses the file Ole32.dll but at the same time wants to replace the Windows 95 version (dated 7/11/95) with its own newer copy (3/8/96 for RTM, 7/2/96 for SP2). Because it has been loaded into memory, Windows must restart to unload the file so it can be replaced.
RESOLUTION
To resolve this problem:
- Replace the existing Win95\System\Ole32.dll file with the newer copy from the share point before running Setup. The file can be extracted from Exchng6.cab if necessary.
Keywords: kbusage KB165135