Article ID: 92792
Article Last Modified on 10/14/1999
APPLIES TO
- Microsoft Windows for Workgroups 3.1
This article was previously published under Q92792
SYMPTOMS
If you are using an NCR MCA 486 system and you choose the Custom option when you run the Windows for Workgroups Setup program, the Setup program fails after you choose which components you want to install. Each time a file is copied, you receive the following error message:
CAUSE
This problem is caused by the default settings in the .ADF configuration files. If the NCR MCA setup is configured for "Automatic Config," the small computer systems interface (SCSI) adapter is resent to DOS 4.01 and sets the logical SCSI device number to 7.
WORKAROUND
To work around this problem, change the DOS version to MS-DOS 5 and the device number to zero.
MORE INFORMATION
This affects NCR MCA systems that have been upgraded to MS-DOS 5.0 when you select "Automatic Config" during MCA Setup.
Additional query words: 3.10 bus WFWFEST
Keywords: KB92792