Microsoft KB Archive/927152

From BetaArchive Wiki
< Microsoft KB Archive
Revision as of 18:34, 18 July 2020 by 3155ffGd (talk | contribs) (importing KB archive)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Knowledge Base


The status bar displays a flashing message or displays alternate messages when you apply a filter to a subreport in Access 2007: "Calculating," "Ready," or another status

Article ID: 927152

Article Last Modified on 10/15/2007



APPLIES TO

  • Microsoft Office Access 2007



SYMPTOMS

When you apply a filter to a subreport in Microsoft Office Access 2007, you may experience the following symptoms:

  • The status bar in Access 2007 displays the following flashing message:

    Calculate

  • The status bar indicates that the status of Access 2007 continually changes. For example, the status bar alternately displays messages such as the following:

    Message 1

    Ready

    Message 2

    Calculating

  • Data that is contained in the report alternates between being visible and not being visible.
  • Data that is contained in the report alternates between #Name and the actual cell value.


STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

MORE INFORMATION

Steps to reproduce the problem

  1. Open a database in Access 2007.
  2. Open a subreport in layout mode.
  3. Click a cell, and then apply a filter.



Additional query words: AC2007 ACC2007 Access2007 flickers flashing flickering

Keywords: kbtshoot kbbug kbprb kbexpertiseinter KB927152