Microsoft KB Archive/829200

From BetaArchive Wiki

Article ID: 829200

Article Last Modified on 7/24/2007



APPLIES TO

  • Microsoft Windows Server 2003, Web Edition
  • Microsoft Windows Server 2003, Standard Edition (32-bit x86)
  • Microsoft Windows Server 2003, Enterprise Edition (32-bit x86)
  • Microsoft Windows Server 2003, Enterprise x64 Edition




SYMPTOMS

When you use the relog command in a script, the script does not work correctly in Microsoft Windows Server 2003. This problem occurs when the following conditions are true:

  • You use the relog command in a script to extract performance counters from performance counter logs and to copy the performance counters to a log file that you create.
  • You set a size limit on the log file that you create.

The script does not work correctly when the size limit is reached.

CAUSE

This problem occurs when the log file size limit is set to 100 megabytes (MB) or higher. The relog command cannot convert binary circular files that are larger than 100 MB.

RESOLUTION

Hotfix information

A supported hotfix is now available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next service pack that contains this hotfix.

To resolve this problem, submit a request to Microsoft Online Customer Services to obtain the hotfix. To submit an online request to obtain the hotfix, visit the following Microsoft Web site:

Note If additional issues occur or any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. To create a separate service request, visit the following Microsoft Web site:

Prerequisites

No prerequisites are required.

Restart requirement

You must restart your computer after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace any other hotfixes.

File information

The English version of this hotfix has the file attributes (or later) that are listed in the following table. The dates and times for these files are listed in coordinated universal time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.

Date         Time   Version           Size     File name
--------------------------------------------------------------
23-Jun-2004  22:34  5.2.3790.186      573,952  Advapi32.dll  

WORKAROUND

To work around this problem, delete the log file before it reaches the 100 MB size limit. Or, set a size limit on the log file that is less than 100 MB.

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

MORE INFORMATION

For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

824684 Description of the standard terminology that is used to describe Microsoft software updates



Additional query words: RELOG.EXE

Keywords: kbhotfixserver kbqfe kbhotfixserver kbqfe kbbug kbfix kbqfe kbwinserv2003presp1fix KB829200