APPLIES TO

  • Microsoft Windows Server 2003, 64-Bit Datacenter Edition
  • Microsoft Windows Server 2003, Enterprise x64 Edition




SYMPTOMS

Time stamps may not be synchronized correctly on a large Symmetric Multiprocessing (SMP) computer that is running Microsoft Windows Server 2003.

CAUSE

This problem may occur if a program queries a Time Stamp Counter (TSC) in one processor for a time stamp, and the Task Scheduler service moves the program to another processor. When the program queries another processor's TSC, the time stamp information is not synchronized with the previous query to the other processor.

RESOLUTION

Hotfix information

A supported hotfix is now available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next service pack that contains this hotfix.

To resolve this problem, submit a request to Microsoft Online Customer Services to obtain the hotfix. To submit an online request to obtain the hotfix, visit the following Microsoft Web site:

Note If additional issues occur or any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. To create a separate service request, visit the following Microsoft Web site:

Prerequisites

No prerequisites are required.

Restart requirement

You must restart your computer after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace any other hotfixes.

File information

The English version of this hotfix has the file attributes (or later) that are listed in the following table. The dates and times for these files are listed in coordinated universal time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.

   Date         Time   Version            Size    File name        Platform
   ------------------------------------------------------------------------
   14-Nov-2003  19:16  5.2.3790.103      305,664  Hal.dll          IA-64

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section of this article.

MORE INFORMATION

For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

824684 Description of the standard terminology that is used to describe Microsoft software updates



Additional query words: sync clock HPET MOW

Keywords: kbhotfixserver kbqfe kbbug kbfix kbqfe kbwinserv2003presp1fix KB827909