Article ID: 822998
Article Last Modified on 7/24/2007
APPLIES TO
- Microsoft Windows Server 2003, Enterprise Edition (32-bit x86)
- Microsoft Windows Server 2003, Enterprise x64 Edition
SYMPTOMS
When Windows unexpectedly stops responding (hangs) and is configured to write debugging information to the Memory.dmp file, the memory-dump operation may not complete successfully. Additionally, you may experience one or both of the following symptoms:
- The memory-dump operation stops responding when it is about 90-percent complete.
- Windows does not automatically restart after the memory-dump operation stops responding.
CAUSE
This problem may occur if you have more than 6 gigabytes (GB) of random access memory (RAM) installed in the computer.
The memory-dump process stops responding in a large memory-dump operation because the ScsiPortGetPhysicalAddress() routine in the Diskdump.sys file returns a value of 0xcb000 instead of 0x1000cb000 to the miniport adapter driver.
RESOLUTION
Hotfix Information
A supported hotfix is now available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next service pack that contains this hotfix.
To resolve this problem, submit a request to Microsoft Online Customer Services to obtain the hotfix. To submit an online request to obtain the hotfix, visit the following Microsoft Web site:
Note If additional issues occur or any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. To create a separate service request, visit the following Microsoft Web site:
Prerequisites
No prerequisites are required to install this hotfix.
Restart Requirement
You must restart your computer to apply the changes after you install this hotfix. However, you do not have to restart the computer immediately after installing this hotfix. If you want to restart later, click to select the Do not restart now check box in the Windows Server 2003 KB822998 Setup Wizard, and then click Finish.
Hotfix Replacement Information
This hotfix does not replace any other hotfixes.
File Information
The English version of this fix has the file attributes (or later) that are listed in the following table. The dates and times for these files are listed in coordinated universal time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.
Windows Server 2003
Date Time Version Size File name ----------------------------------------------------------- 23-Jun-2003 23:46 5.2.3790.66 17,920 Diskdump.sys
Windows Server 2003 64-Bit
Date Time Version Size File name ----------------------------------------------------------- 23-Jun-2003 23:46 5.2.3790.66 47,104 Diskdump.sys
STATUS
Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article.
MORE INFORMATION
This hotfix resolves this problem by using 64-bit arithmetic for the PHYSICAL_ADDRESS calculation.
Keywords: kbhotfixserver kbqfe kbbug kbfix kbqfe kbwinserv2003presp1fix KB822998