Microsoft KB Archive/57922

From BetaArchive Wiki
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Word: Screen Corruption with Adaptec SCSI Controller

PSS ID Number: Q57922 Article last modified on 11-02-1994

5.00

MS-DOS

SUMMARY

Word Version 5.00 may experience screen corruption when it is run on a 80386-based computer with expanded memory that is using an SCSI hard disk drive and the Adaptec SCSI 386-compatible controller card (part number AHA-1542A).

This problem does not occur on 8086-, 8088-, or 80286-based computers. To verify that your screen corruption problem is being caused by Word’s use of expanded memory, try starting Word with the /x switch (word/x). When Word is invoked, this switch will disable Word’s use of expanded memory.

To correct this problem, Adaptec has a device driver called SCSIHA.SYS that can be installed in the 80386 computer’s CONFIG.SYS file.

This device driver can be obtained by contacting Adaptec Technical Support at (408) 745-2550 or by downloading the SCSIHA.SYS device driver from the Adaptec bulletin board service, which can be reached at (408) 945-7727.

KBCategory: kbother KBSubcategory: Additional reference words: