COBOL 2.2 ACCEPT FROM TIME Doesn’t Return Fractional Seconds

PSS ID Number: Q38496 Article last modified on 04-20-1993

2.20 MS-DOS

The information in this article applies to:
- Microsoft COBOL for MS-DOS, version 2.2

Summary: When you compile the program below in Microsoft COBOL Version 2.2, the ACCEPT <identifier> FROM TIME statement always returns “00” in the fractional seconds. The ACCEPT <identifier> FROM TIME statement returns the proper fractional value in Microsoft COBOL Version 3.0. Microsoft has confirmed this to be a problem in Version 2.2. This problem was corrected in Version 3.0.

More Information: The following is a code example: IDENTIFICATION DIVISION. PROGRAM-ID. TIMETEST. ENVIRONMENT DIVISION. DATA DIVISION. WORKING-STORAGE SECTION. 01 WS-TIME. 05 HRS PIC XX. 05 MIN PIC XX. 05 SEC PIC XX. 05 FRC PIC XX. PROCEDURE DIVISION. MAIN-PROGRAM. ACCEPT WS-TIME FROM TIME. DISPLAY WS-TIME. STOP RUN.

Additional reference words: 2.20 Copyright Microsoft Corporation 1993.