Article ID: 254495
Article Last Modified on 2/21/2007
APPLIES TO
- Microsoft Windows 2000 Server
- Microsoft Windows 2000 Advanced Server
- Microsoft Windows 2000 Professional Edition
This article was previously published under Q254495
SYMPTOMS
During a cluster stress test, a connection problem may occur when you perform a failover.
CAUSE
During automatic reconnection for the cluster node, the original connection's mutex is released to make a new connection, and the new connection takes the mutex. However, the new connection is not made, and the original connection's mutex is not retaken.
A mutex is an inter-process synchronization object whose state is set to signaled when it is not owned by any thread, and nonsignaled when it is owned. Only one thread at a time can own a mutex object.
RESOLUTION
To resolve this problem, obtain the latest service pack for Windows 2000. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:
260910 How to Obtain the Latest Windows 2000 Service Pack
STATUS
Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article.
This problem was first corrected in Windows 2000 Service Pack 1.
MORE INFORMATION
For additional information about how to install Windows 2000 and Windows 2000 hotfixes at the same time, click the article number below to view the article in the Microsoft Knowledge Base:
249149 Installing Microsoft Windows 2000 and Windows 2000 Hotfixes
Additional query words: mscs
Keywords: kbhotfixserver kbqfe kbbug kbfix kbqfe kbwin2000sp1fix KB254495