SMS: Liccli95.exe May Hang Windows 95/98 Clients

Article ID: 245228

Article Last Modified on 10/27/2006



APPLIES TO

  • Microsoft Systems Management Server 2.0 Standard Edition
  • Microsoft Systems Management Server 2.0 Service Pack 1



This article was previously published under Q245228

SYMPTOMS

When the Software Metering server is busy handling other requests and a client that is running Microsoft Windows 95 or Microsoft Windows 98 tries to connect to the server, the client may receive a "pipe busy" error message in the Liccli.log file. The client retries 15 times; the client computer may not be useable during this time.

CAUSE

Liccli95.exe may use all the computer resources so that users cannot perform any work. This behavior does not occur with Microsoft Windows NT-based computers because the "Pipe busy" condition is handled differently.

RESOLUTION

To resolve this problem, obtain the latest service pack for Systems Management Server version 2.0. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

236325 How to Obtain the Latest Systems Management Server 2.0 Service Pack


STATUS

Microsoft has confirmed this to be a problem in Systems Management Server version 2.0 This problem was first corrected in Systems Management Server version 2.0 Service Pack 2..


Additional query words: prodsms