Article ID: 235687
Article Last Modified on 3/26/2004
APPLIES TO
- MSMQ - MQSeries Bridge
- Microsoft SNA Server 4.0 Service Pack 2
This article was previously published under Q235687
SYMPTOMS
The Microsoft Message Queue Server ActiveX control returns the following error message:
when receiving a message that was sent from MQSeries over the MSMQ-MQSeries Bridge.
CAUSE
The MSMQ ActiveX Control incorrectly uses an assumed value of 32 bytes for the Security Identifier (SID) buffer length.
STATUS
Microsoft has confirmed this to be a problem in SNA Server version 4.0. This problem has been corrected in the latest U.S. service pack for SNA Server version 4.0. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article.
This problem was first corrected in SNA Server 4.0 Service Pack 3.
Additional query words: MSMQ MQSeries Bridge
Keywords: kbbug kbfix KB235687