SYMPTOMS

When using the offline administrative tool Snacfg.exe to import a script file that contains more than 65,535 lines into a Com.cfg file, if an error occurs, the line number displayed may be incorrect.

CAUSE

The internal counter used by Snacfg.exe was defined as a short, limiting it to 65,535. This has been changed to a long value, which will allow the counter value to be extended to 2,147,483,647.

RESOLUTION

To resolve this problem, obtain the latest service pack for SNA Server version 4.0. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

215838 How to Obtain the Latest SNA Server Version 4.0 Service Pack




STATUS

Microsoft has confirmed that this is a problem in Microsoft SNA Server versions 4.0, 4.0SP1, 4.0SP2. This problem was first corrected in SNA Server version 4.0 Service Pack 3.

MORE INFORMATION

In addition to correcting the line number problem, a new /count parameter was added to Snacfg so that the number of objects in a Com.cfg file can be counted using the tool. Also, performance enhancements were done at this time to improve the performance of Snacfg.exe when parsing large configurations.