Stop 0xA in Tcpip.sys When Token Ring Source Routing Data Exceeds 18 Bytes

Article ID: 179157

Article Last Modified on 11/1/2006



APPLIES TO

  • Microsoft Windows NT Server 4.0, Terminal Server Edition
  • Microsoft Windows NT Workstation 4.0 Developer Edition
  • Microsoft Windows NT Server 4.0 Standard Edition



This article was previously published under Q179157

SYMPTOMS

A computer running Windows NT in a source-routed Token Ring environment may stop randomly with the following blue screen STOP message:

STOP 0x0000000A IRQL_NOT_LESS_OR_EQUAL

CAUSE

This error occurs when Windows NT receives multiple address resolution protocol (ARP) request frames that contain more than the legal amount of Token Ring source routing information. This problem may occur if a source routing bridge does not discard frames with invalid routing information (RI) fields.


RESOLUTION

To resolve this problem, obtain the latest service pack for Windows NT 4.0 or Windows NT Server 4.0, Terminal Server Edition. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

152734 How to Obtain the Latest Windows NT 4.0 Service Pack




STATUS

Microsoft has confirmed that this is a problem in Windows NT 4.0 and Windows NT Server 4.0, Terminal Server Edition. This problem was first corrected in Windows NT 4.0 Service Pack 4.0 and Windows NT Server 4.0, Terminal Server Edition Service Pack 4.


Additional query words: big buffer list corrupt atm 8281