Article ID: 177983
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Server 4.0, Terminal Server Edition
- Microsoft Windows NT Workstation 4.0 Developer Edition
- Microsoft Windows NT Server 4.0 Standard Edition
This article was previously published under Q177983
SYMPTOMS
Your Windows NT server is configured such that the WINS client (TCP/IP) is bound to more than 64 adapter interfaces. When it runs under Windows NT 4.0 with no service packs applied, the computer will stop responding (hang).
If it runs under Windows NT 4.0 with Service Pack 3 applied, your computer may STOP with the following blue screen message:
NOTE: The parameters in the STOP code will be different depending on your configuration, but the first and third parameters will be the same as each other.
CAUSE
A worker routine in Netbt.sys returned at a raised IRQL.
RESOLUTION
To resolve this problem, obtain the latest service pack for Windows NT 4.0 or Windows NT Server 4.0, Terminal Server Edition. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:
152734 How to Obtain the Latest Windows NT 4.0 Service Pack
STATUS
Microsoft has confirmed that this is a problem in Windows NT 4.0 and Windows NT Server 4.0, Terminal Server Edition. This problem was first corrected in Windows NT 4.0 Service Pack 4.0 and Windows NT Server 4.0, Terminal Server Edition Service Pack 4.
Additional query words: crash multiport bindings sixty four ras freeze