Article ID: 175354
Article Last Modified on 10/28/2006
APPLIES TO
- Microsoft Exchange Server 4.0 Standard Edition
- Microsoft Exchange Server 5.0 Standard Edition
- Microsoft Exchange Server 5.5 Standard Edition
This article was previously published under Q175354
SYMPTOMS
When mail is queued to go out through an X.400 connection, the following errors may be logged repeatedly in the event log:
MORE INFORMATION
The time interval "n," in seconds, between the logged errors is equal to the number of seconds set in the X.400 Connector. To check this setting, open the property pages of the X.400 Connector, select the Override tab, in the Connection Retry Values frame, and read the Open Interval(sec) setting.
These errors may be caused by network problems, such as a WAN connection being temporarily down. This does not necessarily indicate a problem with Exchange Server or the Message Transfer Agent (MTA).
As mail is queued to go across the WAN link, the X.400 connector is attempting to re-establish the connection every "n" seconds. Because the WAN connection is down, the MTA transport is not available; the MTA is logging these two events.
Additional query words: x400 repeating
Keywords: kbprb KB175354