Article ID: 174467
Article Last Modified on 7/13/2004
APPLIES TO
- Microsoft SNA Server 3.0 Service Pack 4, when used with:
- Microsoft Windows NT 4.0
- Microsoft SNA Server 4.0, when used with:
- Microsoft Windows NT 4.0
This article was previously published under Q174467
SYMPTOMS
Two separate threads from an SLI application appear to gain access to the SLI critical section, coinciding with an application's SLI call that hangs and never completes. This problem was observed with a Win32 SLI application which supported over 50 different threads, each calling the SLI interface. At times, an SLI call would hang and fail to complete.
CAUSE
The SNA Server Winsli32.dll was not behaving correctly.
STATUS
Microsoft has confirmed this to be a problem in SNA Server version 3.0 and 3.0sp1. This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: critical section hang thread
Keywords: kbbug kbfix kbnetwork KB174467