PRB:Error message - CreateDIBSection failed with error code = 0
PSS ID Number: Q174413 Article last modified on 09-29-1997
IRIX:3.7; WINNT:3.7
IRIX winnt
======================================================================
The information in this article applies to:
- Softimage 3D for IRIX, version 3.7
- == Softimage 3D for Windows NT, version 3.7 ==
SYMPTOMS
While trying to preview, one of the following error messages appears in the SOFTIMAGE 3D Command Prompt:
CreateDIBSection failed with error code = 0
-OR-
worldtoprsp1: divide by zero, transformation ignored
This can also cause SOFTIMAGE 3D to crash without any warnings.
CAUSE
The X resolution and perhaps the X and Y resolution in Preview Setup are set to 0. You must specify a value other than 0 for the X (Y resolution alone does not cause a problem).
RESOLUTION
In the Preview Setup, enter a value other than 0 for the X resolution.
REFERENCES
If you have any questions concerning the information contained in this article, contact support@softimage.com by e-mail. ====================================================================== Keywords : si si3d si3dren kberrmsg Version : IRIX:3.7; WINNT:3.7 Platform : IRIX winnt Issue type : kbprb ============================================================================= Copyright Microsoft Corporation 1997.