Knowledge Base


Creating Connection Gets Error Even If Link Service Selected

Article ID: 171992

Article Last Modified on 6/24/2004



APPLIES TO

  • Microsoft SNA Server 3.0 Service Pack 4
  • Microsoft SNA Server 4.0



This article was previously published under Q171992


SYMPTOMS

When you create a new connection, you may see the following message

Must specify link service field

even though you have already selected a link service field.

CAUSE

Before the connection record is added, its Adapter information is temporarily nulled out and restored after a successful Add. If a value is left in a field on the property page, the Validate fails, causing the Add to fail, an exception to occur, and the Adapter is never restored.

STATUS

Microsoft has confirmed this to be a problem in SNA Server versions 3.0 and 3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K


Keywords: kbbug kbfix kbnetwork KB171992