SYMPTOMS
When you are logged on as an administrator and try to run an executable from the Systems Management Server Installer, the following error message appears:
CAUSE
This problem may occur when the Systems Management Server Installer attempts to write to the client's registry and the configuration requires that the registry contain a subkey that actually has no values in it. This may occur with most Windows NT services that are installed.
WORKAROUND
Add a value with no data, to allow the subkey to be copied and installed, as in the following example:
MainKey SubKey Value = Keep; REG_SZ; Data=""
STATUS
This problem was corrected in the latest version of the Systems Management Server Installer.
MORE INFORMATION
Additional query words: prodsms
Keywords: kbbug kbenv kbfix KB171067