Microsoft KB Archive/169218

From BetaArchive Wiki
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
Knowledge Base


Article ID: 169218

Article Last Modified on 8/27/1999



APPLIES TO

  • Microsoft Open Database Connectivity 3.0



This article was previously published under Q169218

BUG #: 4622 (ODBC30)

SYMPTOMS

When SQL_ODBC_CURSORS is set to SQL_CUR_USE_ODBC using the SQLSetConnectOption and a connection to a data source is made, the next call to SQLSetConnectOption to set the SQL_CURRENT_QUALIFIER or SQL_ATTR_CURRENT_CATALOG fails with the following message:

szSqlState = "S1009", *pfNativeError = 0, *pcbErrorMsg = 55
szErrorMsg = "[Microsoft][ODBC Driver Manager] Invalid argument value"

WORKAROUND

To work around this problem, use SQLSetConnectOption to set the SQL_ODBC_CURSORS to SQL_CUR_USE_IF_NEEDED or SQL_CUR_USE_DRIVER. The ODBC Cursor Library version 3.00.2822 resolves this issue.

STATUS

Microsoft has confirmed this to be a problem in Microsoft Open Database Connectivity version 3.0. This problem has been corrected in U.S. Service Pack 1 for Microsoft Open Database Connectivity, version 3.0. For more information, contact your primary support provider.

MORE INFORMATION

This behavior is only seen with ODBC 2.X applications using a Driver Manager 3.0 and a 2.X ODBC driver.


Additional query words: DM Cursorlibrary

Keywords: kbbug kbfix kbprogramming KB169218