Article ID: 168303
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Workstation 4.0 Developer Edition
- Microsoft Windows NT Server 4.0 Standard Edition
This article was previously published under Q168303
SYMPTOMS
You may receive the following error message in the system log of Event Viewer when you use a PC Card:
CAUSE
This problem occurs when the PC Card attempts to use an IRQ that is already in use.
RESOLUTION
Windows NT does not provide a user interface to set a PC Card to a specific IRQ. Therefore, you must edit the registry to resolve this problem.
NOTE: For these steps to work, you must already have Windows NT installed on the computer that has the PC Card connected to it.
WARNING: Using Registry Editor incorrectly can cause serious, system-wide problems that may require you to reinstall Windows NT to correct them. Microsoft cannot guarantee that any problems resulting from the use of Registry Editor can be solved. Use this tool at your own risk.
Use Registry Editor to perform the following steps:
Start Registry Editor (Regedt32.exe), and go to the following subkey:
HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\Pcmcia
- On the Edit menu, click Add Value.
Add the following values:
Value Name: InterruptMask Data Type: REG_DWORD Data: see note below RADIX: HEX
NOTE: The Data field will actually be a four digit hexadecimal number. To determine the value of the data field you must know which IRQ's you are trying to mask or hide. You must also know what the valid IRQ's are for this card. You can use the Pcmcmd.exe command from the Support\Debug\i386 directory on the Windows NT 4.0 CD. Look for the IRQ Level Mask to get the valid IRQ's for the card.
Each IRQ is represented by it's associated binary place holder 0 - 15. Each of the four hexadecimal numbers in the Data field represent 4 binary digits of the Interrupt Mask. So if we had a PCMCIA card that could take IRQ 11, 10, 9, 7, 5, and 3, the default InterruptMask would be f157. Also, if you wanted to mask IRQ 5, you would set the 5th digit to 1 which could be achieved with a DATA value of f177. This would look similar to the following table:
IRQ's: 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 VALUE: 1 1 1 1 0 0 0 1 0 1 1 1 0 1 1 1 = f177
A value of 1 in the mask makes the IRQ unavailable. A value of 0 leaves it available. With the preceding example, the f of f177 masks IRQ's 12- 15, the 1 of f177 leaves IRQ 9, 10, 11, but masks 8. The middle 7 of f177 mask IRQ 4-6 and leaves 7 available, and the last 7 of f177 mask 0- 2 and leaves 3 available.- Click OK, and then exit Regedt32.
- Restart the computer and the PC Card should no longer select IRQ 5.
Additional query words: prodnt pccard hardware conflict