Article ID: 166709
Article Last Modified on 9/30/2003
APPLIES TO
- Microsoft Commercial Internet System 1.0 Service Pack 2
This article was previously published under Q166709
SYMPTOMS
The Internet News Server (INS) only allows postings from a moderated news group to the same group on another server as long as the moderators match. If the moderators do not match, you will get the following error message In the log:
CAUSE
INN supports feeds from one server to the other with different moderators for the same news group; for example:
Server 1 Server 2 Newsgroup Newsgroup Moderator 1 Moderator 2
Posting to server 1, approving with moderator 1, the posting will never get to Server 2 with the correct feeds set.
WORKAROUND
Remove the moderator on server2. This will allow the posting to proceed without getting the 502 error message.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Commercial Internet System version 1.0. This problem has been corrected in the latest U.S. Service Pack for Microsoft Commercial Internet System version 1.0. For information on obtaining the Service Pack, query on the following article in the Microsoft Knowledge Base:
183062 MCIS 1.0 Service Packs 1 and 2 Information
Additional query words: sp2 ins
Keywords: kbbug kbfix KB166709