SUMMARY

This document contains answers to Frequently Asked Questions (FAQ) about the Active Template Library (ATL) versions 2.0 and 2.1. Here is a list of the questions that are answered:

Questions on ATL 2.0 Setup

  1. What are the known problems with the ATL 2.0 Object Wizard? (3/5/97)

Questions on ATL controls

  1. Why is the put_Font or putref_Font method not called when an ActiveX control's Font property is changed by the ActiveX Control Pad? (3/5/97)
  2. How do I get the <PARAM> tag to work with an ATL control? (3/5/97)
  3. What DLLs do I need to ship with my control? (3/12/97)
  4. What changes does a control need to run in the Visual Basic 5.0 Control Creation Edition? (3/12/97)
  5. What changes does a control need to run in an MFC 4.2b container? (3/12/97)
  6. Why do I get exceptions when debugging my control? What do they mean? (3/12/97)
  7. Why doesn't the container use my connection point interface? (4/2/97)

Questions on DLLs

  1. What are the reasons an ATL server might fail to register? (3/5/97)
  2. What problems might be encountered when using _ATL_MIN_CRT? What causes the linker error that _main is unresolved during Release builds? (3/5/97)
  3. What are the known problems with the ATL 2.0 Object Wizard? (3/5/97)
  4. What DLLs do I need to ship with my control? (3/12/97)

Questions on registration

  1. What are the reasons an ATL server might fail to register? (3/5/97)
  2. How do I update the CLSID registry key under a version-independent ProgID? (3/5/97)


MORE INFORMATION

Q. Why is the put_Font or putref_Font method not called when an ActiveX control's Font property is changed by the ActiveX Control Pad?

The following also applies to ATL 3.0:

A. The put_Font or putref_Font method is called only when you completely replace your control's Font object with a new one. When you change the font in the ActiveX Control Pad, get_Font is called to get a pointer to the Font object for the ActiveX Control Pad. Changes made by the Control Pad are made directly to that object. The ActiveX Control Pad does not create a new Font object and assign it to your Font property.

The following example demonstrates the case where the font property is changed without calling the put_Font or putref_Font method:

   <object CLASSID="clsid:E882D673-878E-11D0-B00C-000000000000"
    id="FontTest1">
   </object>
   <object CLASSID="clsid:E882D673-878E-11D0-B00C-000000000000"
    id="FontTest2">
   </object>
   <SCRIPT LANGUAGE="VBScript">
   <!--
   Sub Window_OnLoad

   FontTest1.Font.Name = "times new roman"
   FontTest1.Font.Size = 16
   FontTest2.Font = FontTest1.Font

   End Sub
   -->
   </SCRIPT>
                


Q. How do I get the <PARAM> tag to work with an ATL control?

The following also applies to ATL 3.0:

A. You need to support the IPersistPropertyBag interface for the HTML <PARAM> tag to work with your ATL control. An implementation of this interface is supplied in the IPersistPropertyBagImpl class that comes with ATL 2.1. The CIRC sample demonstrates how to support IPersistPropertyBag and add your properties to the property map.




Q. What are the reasons an ATL server might fail to register?

The following also applies to ATL 3.0:

A. The following are the top three reasons an ATL server might fail to register:

  1. You built your project with _WIN32_WINNT=0x400 (the default), and you are not running the ATL server under Windows NT 4.0 or you do not have an up-to-date version of Oleaut32.dll. To solve this problem, run "DUMPBIN /EXPORTS OLEAUT32.DLL" and search for UnregisterTypelib. If it is not there, then your server cannot run. Remove this #define statement from Stdafx.h if you want to run the ATL server under Windows 95 or older versions of Windows NT. Alternatively, you can use LoadLibrary and GetProcAddress so that you can run optimally under both Windows 95 and Windows NT 4.0. The Oleaut32.dll that ships with the Internet Explorer 3.x is up-to-date.
  2. You built your project as MinSize and Atl.dll is not properly installed on the system. The correct version of Atl.dll must be copied and registered by Regsvr32. There are Windows NT and Windows 95 versions of Atl.dll. The Windows 95 version runs under Windows NT. However, since it does not use the UNICODE APIs, it is slightly less efficient. Unless you build your project as MinDependency, you will need to install the correct version of Atl.dll and run Regsvr32 on it before you install your server.
  3. You built your project as UNICODE, and you cannot run it under Windows 95.

The following are the steps to troubleshoot:

  1. For a DLL server, run Regsvr32 in the debugger. Open the Project Settings dialog box and click the Debug tab. In the Executable for debug session text box, enter the full path to Regsvr32.exe, such as C:\Sharedide\Bin\Regsvr32.exe. In the Program arguments text box, specify the full path to your DLL, such as C:\Myprojects\MyFolder\Debug\MyFile.dll. Set a breakpoint at DllRegisterServer and start stepping.
  2. For an EXE server, run it in the debugger and specify /REGSVR as its command-line argument.




Q. What problems might be encountered when using _ATL_MIN_CRT? What causes the linker error that _main is unresolved during Release builds?

The following also applies to ATL 3.0:

A. This usually happens when the C Run-Time (CRT) startup code is required for some CRT functions. You can either remove all references to the CRT functions that require the startup code or remove the _ATL_MIN_CRT preprocessor definition from your compiler settings.

You can link statically or dynamically to the CRT. Statically linking causes the CRT code to be placed in your executable image and you do not need to have the CRT DLL (Msvcrt.dll). If you dynamically link to the CRT, references to the code in Msvcrt.dll are placed in your image. For your image to run, Msvcrt.dll must be present. Even when dynamically linking to the CRT, there can still be some code statically linked, such as DllMainCRTStartup.

An entry point, explicitly or implicitly specified when linking, is called by the operating system after loading the image. For a DLL, the default entry point is DllMainCRTStartup. For an EXE, it is WinMainCRTStartup. You can override the default with the /ENTRY linker option. The CRT provides an implementation for DllMainCRTStartup, WinMainCRTStartup, and wWinMainCRTStartup (UNICODE entry point for an EXE). These entry points (CRT startup code) call constructors on global objects and initialize some data structures used by some CRT functions. This startup code adds about 25K to your image when statically linking.

Some CRT functions can be used without the CRT startup code, for example, functions with the mem prefix, wcslen, wcscmp, and strlen. The following require the CRT startup code:

  • String comparison routines
  • Memory allocation routines
  • Global objects with constructors
  • C++ exception handling (/GX)

ATL is aimed at minimizing the image size and the reliance on run-time DLLs. It provides alternative implementations for common CRT APIs that would otherwise require the CRT startup code. The use of these APIs is controlled by the _ATL_MIN_CRT macro. Using _ATL_MIN_CRT does not mean that you cannot use the CRT routines. However, if you use the routines that require the CRT startup code, then you will get a linker error that _main is unresolved. Providing your own implementation of _main does not solve this problem.

If C++ exceptions (/GX) are enabled, then you must link in the startup code. The _ATL_MIN_CRT macro cannot be used in this case. MFC requires code to be compiled with the /GX option. Therefore, you cannot use _ATL_MIN_CRT in conjunction with MFC. You can use SEH (structured exception handling), __try, and __except with _ATL_MIN_CRT, because the startup code is not required. In many cases, since most of the CRT source code ships with the product, you can use some of this code and replace only parts of it with system calls to avoid the startup code.

To find out what is causing the problem, do one of the following:

  • Open the Project Settings dialog box, select the Link tab, and click Input in the Category box. Type LIBCMT.LIB in the Ignore libraries text box. Now do a build. You will get a list of unresolved externals. This list contains the CRT routines you are using. Look for the routines that you think may require the startup code.
  • Turn on the /VERBOSE linker option. From the resulting linker output, you can find a list of routines that require the CRT startup code.

If you need the startup code, then remove the _ATL_MIN_CRT definition from the Project Settings. You can also dynamically link to CRT. This reduces your image size but requires Msvcrt.dll.

When building as Release, the default option is to statically link to CRT and use _ATL_MIN_CRT. This gives a smaller image size than dynamically linking to CRT, at least when the startup code is avoided and the CRT APIs used by AppWizard are used.




Q. How do I update the CLSID registry key under a version-independent ProgID? Or, why is CLSIDFromProgID failing when passing a version independent ProgID?

This problem was fixed in ATL version 3.0.

A. Using the CLSIDFromProgID function fails when you pass a version independent ProgID with only a CurVer key. To make it work, you need to add the CLSID key under the version-independent ProgID.

If in your .RGS file, you have:

   TriBrowseObj.TriBrowseObj.1 = s 'TriBrowseObj Class'
   {
         CLSID = s '{3452E30B-8B87-11D0-A671-00A0C903977C}'
   }
   TriBrowseObj.TriBrowseObj = s 'TriBrowseObj Class'
   {
         CurVer = s 'TriBrowseObj.TriBrowseObj.1'
   }

you must change it to:

   TriBrowseObj.TriBrowseObj.1 = s 'TriBrowseObj Class'
   {
           CLSID = s '{3452E30B-8B87-11D0-A671-00A0C903977C}'
   }
   TriBrowseObj.TriBrowseObj = s 'TriBrowseObj Class'
   {
           CLSID = s '{3452E30B-8B87-11D0-A671-00A0C903977C}'
           CurVer = s 'TriBrowseObj.TriBrowseObj.1'
   }
                

To fix this problem for the future, modify the wizard template (.rgs) in the following directory:

  • For Visual C++ 4.x: \Msdev\Template\Atl
  • For Visual C++ 5.0: \Devstudio\Sharedide\Template\Atl

Change the Control.rgs file and any other .rgs files that are wrong. The following statements:

  [!ProgID] = s '[!TypeName]'
  {
   CLSID = s '{[!ObjectGUID]}'
[!if=(InsertableEnabled, "TRUE")]
   'Insertable'
[!endif]
  }
[!VersionIndependentProgID] = s '[!TypeName]'
  {
   CurVer = s '[!ProgID]'
  }

should be changed to:

   [!ProgID] = s '[!TypeName]'
   {
     CLSID = s '{[!ObjectGUID]}'
[!if=(InsertableEnabled, "TRUE")]
    'Insertable'
[!endif]
   }
   [!VersionIndependentProgID] = s '[!TypeName]'
   {
     CLSID = s '{[!ObjectGUID]}'
     CurVer = s '[!ProgID]'
   }
                


Q. What are the known problems with the ATL 2.0 Object Wizard?

A. The ATL 2.0 Object Wizard might not be present in the Component Gallery. The ATL 2.0 Object Wizard is not installed by the main ATL 2.0 setup program (Atlinst.exe). It requires a separate setup program. You need to download and run the ATL 2.0 Object Wizard Technology Preview (Objinst.exe) from the ATL Web page. There is a separate ZIP file for Windows NT 3.51.

The ATL 2.0 Object Wizard may crash if an older version of Oleaut32.dll is installed on the system. Make sure the version of Oleaut32.dll is at least 2.20.4049. The latest version is available for download at the Internet Explorer 3.x Web site. If this does not fix the problem, then install Service Pack 2 for Windows NT 4.0.




Q. What DLLs do I need to ship with my control?

The following also applies to ATL 3.0:

A. If you build your control with the MinDependency option, the resulting DLL (or EXE) is completely self contained. The control relies only on standard system DLLs such as Kernel32, User32, Gdi32, Ole32, Oleaut32, and Advapi32. You need to distribute another DLL only when you build a proxy/stub DLL that is not a part of your server DLL.

If you build with the MinSize option, you are required to ship only Atl.dll with your control. You should statically link to the C Run-Time (CRT) Libraries. In case you do not need the CRT startup code, and with minimal use of the CRT, statically linking to the CRT produces a smaller image size than dynamically linking.




Q. What changes does a control need to run in the Visual Basic 5.0 Control Creation Edition?

This problem was fixed in the Visual Studio 97 Service Pack 1.

A. If your control supports connection points and the IQuickActivate interface, then it must support the IPropertyNotifySink connection point for Visual Basic 5.0. To support the IPropertyNotifySink connection point, add the following to the inheritance list:

   public IPropertyNotifySinkCP<CYourControlName>
                

And add the following to your connection point map:

   CONNECTION_POINT_ENTRY(IID_IPropertyNotifySink)
                


Q. What changes does a control need to run in an MFC 4.2b container?

The following also applies to ATL 3.0:

A. There is a problem with MFC 4.2b in setting up the event sink when the IQuickActivate interface is used. The workaround is to comment out the following line in your interface map:

   COM_INTERFACE_ENTRY_IMPL(IQuickActivate)
                

You can also remove the following line from your inheritance list:

   public IQuickActivateImpl<CYourControlName>
                


Q. Why do I get exceptions when debugging my control? What do they mean?

The following also applies to ATL 3.0:

A. Running the debugger in an environment that supports Structured Exception Handling (SEH), like Windows NT, may produce exceptions like the following:

First-chance exception in MY.OCX (KERNEL32.DLL): 0xC0000005:
Access Violation.

These exceptions occur at a lower level in the system than your control. For more information, see the Microsoft Knowledge Base article: 105675.




Q. Why doesn't the container use my connection point interface?

The following also applies to ATL 3.0:

A. Make sure your outgoing interface is not defined as a dual interface. If the connection point specifies an outgoing interface as a dual interface, most containers are not able to create a sink object to connect to that connection point. Containers that provide connection sinks for COM objects have to dynamically create those sinks. If you specify a dual interface, it would be possible for events to be fired using the IDispatch part of the dual interface. It is also possible that the COM object fires events through the custom or v-table part of the dual interface that is not implemented by most containers. Therefore, most containers protect against hooking up a connection to a dual interface. The alternative is to use a dispinterface. Containers such as Visual Basic 5.0 and Internet Explorer only allows a dispinterface to be connected.

If you implement both the sink and the source, then it is recommended that you use a dual interface for connection points. See the ATL Connect sample for more information.