Microsoft KB Archive/161919

From BetaArchive Wiki
Knowledge Base


Article ID: 161919

Article Last Modified on 1/19/2007



APPLIES TO

  • Microsoft Word 97 Standard Edition



This article was previously published under Q161919


SYMPTOMS

When you control Word for Windows 97 from another application using OLE Automation, as in the following example:

Sub WordTask()
   Dim appWd As Object
   Set appWd = CreateObject("Word.Application")
   Set appWd = Nothing
End Sub
                

Word remains loaded in memory (even though the code uses the Set statement to set the instance of Word to "Nothing").

NOTE: IF you press CTRL+ALT+DELETE to bring up the Windows Task List, you see that "Winword" is still running.

WORKAROUND

Microsoft provides programming examples for illustration only, without warranty either expressed or implied, including, but not limited to, the implied warranties of merchantability and/or fitness for a particular purpose. This article assumes that you are familiar with the programming language being demonstrated and the tools used to create and debug procedures. Microsoft support professionals can help explain the functionality of a particular procedure, but they will not modify these examples to provide added functionality or construct procedures to meet your specific needs. If you have limited programming experience, you may want to contact a Microsoft Certified Partner or the Microsoft fee-based consulting line at (800) 936-5200. For more information about Microsoft Certified Partners, please visit the following Microsoft Web site:

For more information about the support options that are available and about how to contact Microsoft, visit the following Microsoft Web site:

The proper method to use when ending a Word OLE Automation session is to use the Quit method. For example:

Sub WordTask()
   Dim appWd As Object
   Set appWd = CreateObject("Word.Application")
   ' Quit the Word session.
   appWd.Quit
   ' Set the Word OLE Object to nothing to free
   ' the appWd object memory.
   Set appWd = Nothing
End Sub
                

MORE INFORMATION

For additional information, please see the following article in the Microsoft Knowledge Base:

173707 OFF97: How to Run Sample Code from Knowledge Base Articles


REFERENCES

For more information about getting help with Visual Basic for Applications, please see the following article in the Microsoft Knowledge Base:

163435 VBA: Programming Resources for Visual Basic for Applications



Additional query words: wordcon vb vba vbe

Keywords: kbdtacode kbmacroexample kbnofix kbprb KB161919