Article ID: 157699
Article Last Modified on 10/28/2006
APPLIES TO
- Microsoft Exchange Server 4.0 Service Pack 1
- Microsoft Exchange Server 4.0 Service Pack 2
This article was previously published under Q157699
SYMPTOMS
The Microsoft Exchange Message Transfer Agent (MTA) will fail to process Read and Delivery Receipts when messages are sent from Microsoft Exchange to a Wang Office Gateway via the Microsoft Exchange X.400 Connector.
CAUSE
The MTA does not handle the Per Message Flag as specified in the 1984 X.400 specification.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange Server version 4.0. This problem was corrected in the latest Microsoft Exchange Service Pack. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: wang 1984 red book sp3 p1 envelope
Keywords: kbusage KB157699